Results 1 - 20 de 43
Filter
1.
Microbiol Spectr ; 12(4): e0416423, 2024 Apr 02.
Article in English | MEDLINE | ID: mdl-38441465

ABSTRACT

We conducted a comparative evaluation of the FDA-cleared Simplexa GBS Direct and ARIES GBS molecular assays for the detection of Streptococcus agalactiae (Group B Streptococcus, GBS) in 386 prospectively collected, broth-enriched vaginal/rectal swab specimens. The sensitivity of each test was 96.2% and specificity was ≥98.7% when compared to a combined direct and enriched culture method using chromogenic culture medium. A total of four specimens were called positive by both molecular assays but negative by culture, likely representing specimens with a low burden of GBS in these specimens. Two specimens were reported positive by culture but negative by both molecular assays. One of these specimens demonstrated atypically colored colonies on chromogenic agar; the other yielded typically colored colonies only observed after broth enrichment. Our data demonstrate equivalent performance of Simplexa and ARIES molecular assays for the detection of GBS in clinical specimens.IMPORTANCEClinical laboratories often face decisions regarding which of the multiple available molecular platforms would best fit their needs based on cost, workflow, menu, and diagnostic performance. Therefore, objective clinical comparisons of similar molecular tests are valuable resources to aid these decisions. We provide a clinical comparison of two FDA-cleared tests to routine culture and to each other that can be used by clinical laboratories when determining which of the available molecular platforms would best fit their laboratory in terms of workflow, cost, and performance.


Subject(s)
Pregnancy Complications, Infectious , Streptococcal Infections , Pregnancy , Female , Humans , Pregnancy Complications, Infectious/diagnosis , Vagina , Sensitivity and Specificity , Streptococcal Infections/diagnosis , Rectum , Streptococcus agalactiae/genetics
2.
J Clin Microbiol ; 61(11): e0082723, 2023 11 21.
Article in English | MEDLINE | ID: mdl-37902331

ABSTRACT

The symptomology is overlapping for respiratory infections due to severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2), influenza A/B viruses, and respiratory syncytial virus (RSV). Accurate detection is essential for proper medical management decisions. This study evaluated the clinical performance of the Panther Fusion SARS-CoV-2/Flu A/B/RSV assay in nasopharyngeal swab (NPS) specimens from individuals of all ages with signs and symptoms of respiratory infection consistent with COVID-19, influenza, or RSV. Retrospective known-positive and prospectively obtained residual NPS specimens were collected during two respiratory seasons in the USA. Clinical performance was established by comparing Panther Fusion SARS-CoV-2/Flu assay results to a three-molecular assay composite comparator interpretation for SARS-CoV-2 and to the FDA-cleared Panther Fusion Flu A/B/RSV assay results for all non-SARS-CoV-2 targets. A total of 1,900 prospective and 95 retrospective NPS specimens were included in the analyses. The overall prevalence in prospectively obtained specimens was 20.7% for SARS-CoV-2, 6.7% for influenza A, and 0.7% for RSV; all influenza B-positive specimens were retrospective specimens. The positive percent agreement of the Panther Fusion assay was 96.9% (378/390) for SARS-CoV-2, 98.0% (121/123) for influenza A virus, 95.2% (20/21) for influenza B virus, and 96.6% (57/59) for RSV. The negative percent agreement was ≥98.5% for all target viruses. Specimens with discordant Panther Fusion SARS/Flu/RSV assay results all had cycle threshold values of ≥32.4 (by comparator or by Panther Fusion SARS/Flu/RSV assay). Only five co-infections were detected in the study specimens. The Panther Fusion SARS-CoV-2/Flu/RSV assay provides highly sensitive and specific detection of SARS-CoV-2, influenza A virus, influenza B virus, and RSV in NPS specimens.


Subject(s)
COVID-19 , Influenza A virus , Influenza, Human , Respiratory Syncytial Virus Infections , Respiratory Syncytial Virus, Human , Respiratory Tract Infections , Humans , Influenza, Human/diagnosis , SARS-CoV-2 , Retrospective Studies , Prospective Studies , Respiratory Syncytial Virus Infections/diagnosis , Nasopharynx , COVID-19/diagnosis , Sensitivity and Specificity , Influenza B virus , Respiratory Tract Infections/diagnosis
3.
J Clin Virol ; 166: 105532, 2023 09.
Article in English | MEDLINE | ID: mdl-37459763

ABSTRACT

BACKGROUND: The SARS-CoV-2 pandemic saw the rapid rise, global spread, and diversification of the omicron variant in 2022. Given the overwhelming dominance of this variant globally and its diverse lineages, there is an urgent need to ensure that diagnostic assays are capable of detecting widely circulating omicron sub-lineages. STUDY DESIGN: Remnant clinical VTM samples from SARS-CoV-2 PCR confirmed infections (n = 733) collected in Wisconsin (n = 94), New York (n = 267), and South Carolina (n = 372) throughout 2022 were sequenced, classified, and tested with m2000 RealTime SARS-CoV-2, Alinity m SARS-CoV-2, ID NOW COVID-19 v2.0, BinaxNOW COVID-19 Ag Card, and Panbio COVID-19 Rapid Test Device assays. RESULTS: Sequences and lineage classifications were obtained for n = 641/733 (87.4%) samples and included delta (n = 6) and representatives from all major SARS-CoV-2 omicron variants circulating in 2022 (BA.1, BA.2, BA.3, BA.4, BA.5, BE, BF, BQ.1, and XBB). Panels of diverse omicron lineages were tested by molecular assays RealTime (n = 624), Alinity m (n = 80), and ID NOW v2.0 (n = 88) with results showing 100% detection for all samples. BinaxNOW and Panbio had sensitivities of 494/533 (92.7%) and 416/469 (88.7%), respectively for specimens with >4 log10 copies/test, consistent with expected performance for frozen specimens. Furthermore, BinaxNOW demonstrated SARS-CoV-2 detection in clinical samples 1-4 days, and up to 18 days post-symptom onset in BA.1 infected patients with >4 log10 copies/test. CONCLUSIONS: This data highlights the rise and diversification of SARS-CoV-2 omicron variants over the course of 2022 and demonstrate that each of the 5 tested assays can detect the breadth of omicron variants circulating globally.


Subject(s)
COVID-19 , Humans , COVID-19/diagnosis , SARS-CoV-2/genetics , Biological Assay , Immunologic Tests
4.
Clin Chem Lab Med ; 61(8): 1511-1517, 2023 07 26.
Article in English | MEDLINE | ID: mdl-36799248

ABSTRACT

OBJECTIVES: To evaluate pre-analytical challenges related to high-volume central laboratory SARS-CoV-2 antigen testing with a prototype qualitative SARS-CoV-2 antigen immunoassay run on the automated Abbott ARCHITECT instrument. METHODS: Contrived positive and negative specimens and de-identified nasal and nasopharyngeal specimens in transport media were used to evaluate specimen and reagent on-board stability, assay analytical performance and interference, and clinical performance. RESULTS: TCID50/mL values were similar for specimens in various transport media. Inactivated positive clinical specimens and viral lysate (USA-WA1/2020) were positive on the prototype immunoassay. Within-laboratory imprecision was ≤0.10 SD (<1.00 S/C) with a ≤10% CV (≥1.00 S/C). Assay reagents were stable on board the instrument for 14 days. No high-dose hook effect was observed with a SARS-CoV-2 stock of Ct 13.0 (RLU>1.0 × 106). No interference was observed from mucin, whole blood, 12 drugs, and more than 20 cross-reactants. While specimen stability was limited at room temperature for specimens with or without viral inactivation, a single freeze/thaw cycle or long-term storage (>30 days) at -20 °C did not adversely impact specimen stability or assay performance. Specificity of the prototype SARS-CoV-2 antigen immunoassay was ≥98.5% and sensitivity was ≥89.5% across two ARCHITECT instruments. Assay sensitivity was inversely correlated with Ct and was similar to that reported for the Roche Elecsys® SARS-CoV-2 Ag immunoassay. CONCLUSIONS: The prototype SARS-CoV-2 antigen ARCHITECT immunoassay is sensitive and specific for detection of SARS-CoV-2 in nasal and nasopharyngeal specimens. Endogenous proteases in mucus may degrade the target antigen, which limits specimen storage and transport times and complicates assay workflow.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Sensitivity and Specificity , COVID-19 Testing , Immunoassay
5.
J Clin Microbiol ; 60(12): e0135622, 2022 12 21.
Article in English | MEDLINE | ID: mdl-36472424

ABSTRACT

Early-onset neonatal sepsis due to Streptococcus agalactiae (group B Streptococcus [GBS]) infection is one of the leading causes of newborn mortality and morbidity. The latest guidelines published in 2019 recommended universal screening of GBS colonization among all pregnant women and intrapartum antibiotic prophylaxis for positive GBS. The updated procedures allow rapid molecular-based GBS screening using nutrient broth-enriched rectovaginal samples. Commercially available molecular assays for GBS diagnosis target mainly the cfb gene, which encodes a hemolysin protein responsible for producing the Christie-Atkins-Munch-Petersen (CAMP) factor. cfb is considered a conserved gene in essentially all GBS isolates. However, false-negative GBS results on Cepheid Xpert GBS and GBS LB tests due to deletions in or near the region that encodes cfb were reported recently. Therefore, the new Xpert GBS LB XC test was developed. This study is a multicenter evaluation of the new test for GBS identification from nutrient broth-enriched rectal/vaginal samples from antepartum women. A total of 621 samples were prospectively enrolled. The samples were tested with the Xpert GBS LB XC test, the composite comparator method, which included the Hologic Panther Fusion GBS test combined with bacterial culture, followed by matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) identification, and bacterial culture alone, followed by MALDI-TOF MS identification. The respective sensitivity and specificity of the Xpert GBS LB XC test were 99.3% and 98.7% compared to the composite comparator method and 99.1% and 91.8% compared to bacterial culture alone with MALDI-TOF MS identification. Overall, the Xpert GBS LB XC test performed comparatively to the composite comparator method and is equivalent to traditional bacterial culture followed by MALDI-TOF MS.


Subject(s)
Pregnancy Complications, Infectious , Streptococcal Infections , Infant, Newborn , Pregnancy , Female , Humans , Pregnancy Complications, Infectious/diagnosis , Pregnancy Complications, Infectious/microbiology , Vagina/microbiology , Streptococcus agalactiae/genetics , Streptococcal Infections/diagnosis , Streptococcal Infections/microbiology , Sensitivity and Specificity
6.
Sci Rep ; 12(1): 18525, 2022 11 02.
Article in English | MEDLINE | ID: mdl-36323751

ABSTRACT

Within healthcare settings, physicians use antibiograms, which offer information on local susceptibility rates, as an aid in selecting empirical antibiotic therapy and avoiding the prescription of potentially ineffective drugs. While antibiograms display susceptibility and resistance data at hospital, city, or region-specific levels and ultimately enable the initiation of antibiogram-based empirical antibiotic treatment, AST reports at the individual patient level and guides treatments away from broad-spectrum antibiotics towards narrower-spectrum antibiotics or the removal of antibiotics entirely. Despite these advantages, AST traditionally requires a 48- to 72-h turn-around; this window of time can be critical for some antimicrobial therapeutic interventions. Herein, we present a direct-from-specimen AST to reduce the time between patient sampling and receipt of lab AST results. The biggest challenge of performing AST directly from unprocessed clinical specimens with an unknown microbial load is aligning the categorical susceptibility report with CLSI reference methods, which start from a fixed inoculum of 0.5 McFarland units prepared using colonies from a sub-culture. In this pilot clinical feasibility study using de-identified remnant specimens collected from MCW, we observed the high and low ends of microbial loads, demonstrating a final categorical agreement of 87.5% for ampicillin, 100% for ciprofloxacin, and 100% for sulfamethoxazole-trimethoprim.


Subject(s)
Anti-Bacterial Agents , Ciprofloxacin , Humans , Feasibility Studies , Microbial Sensitivity Tests , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/therapeutic use , Ciprofloxacin/pharmacology , Ciprofloxacin/therapeutic use , Ampicillin
7.
Diagn Microbiol Infect Dis ; 104(2): 115764, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35917666

ABSTRACT

The COVID-19 pandemic highlighted the significance of readily available and easily performed viral testing for surveillance during future infectious pandemics. The objectives of this study were: to assess the performance of the Xpert Xpress Flu and/or RSV test, a multiplex PCR assay for detecting influenza A and B virus and respiratory syncytial virus nucleic acids in respiratory tract specimens, relative to the Quidel Lyra Influenza A+B assay and the Prodesse ProFlu+ assay, and the system's ease of use by minimally trained operators. Overall, the Xpert Xpress Flu/RSV test demonstrated a high positive and negative percent agreement with the comparator assays, and was easy to use and interpret results, based on the operators' feedback. We concluded that the Xpert Xpress Flu/RSV test is sensitive, specific, and easy to use for the diagnosis of influenza and RSV by minimally trained operators and can be a valuable tool in future infectious clusters or pandemics.


Subject(s)
COVID-19 , Influenza A virus , Influenza, Human , Respiratory Syncytial Virus Infections , Respiratory Syncytial Virus, Human , COVID-19/diagnosis , Humans , Influenza A virus/genetics , Influenza B virus/genetics , Influenza, Human/diagnosis , Molecular Diagnostic Techniques/methods , Nasopharynx , Pandemics , Real-Time Polymerase Chain Reaction/methods , Respiratory Syncytial Virus Infections/diagnosis , Respiratory Syncytial Virus, Human/genetics , Sensitivity and Specificity
8.
Diagn Microbiol Infect Dis ; 102(1): 115554, 2022 Jan.
Article in English | MEDLINE | ID: mdl-34678712

ABSTRACT

We conducted an international multicentre evaluation to assess the clinical performance characteristics of the new multiplex PCR-based BD MAX Check-Points CPO assay to detect the 5 major carbapenemase families: KPC, VIM/IMP (tested simultaneously), NDM and OXA-48 compared to a reference method consisting of 2 culture methods (to improve recovery of CPO isolates from the rectal swabs), followed by carbapenem susceptibility testing and sequencing of target carbapenemase genes. Tests were performed from rectal swab specimens in ESwab collection and transport devices. Positive percent agreement (PPA) for BD MAX Check-Points CPO for KPC and OXA-48 were 88.2% (95% CI:72.6-96.7) and 96.2% (95% CI:80.4-99.9), respectively. Negative percent agreement was ≥99% for each gene. Insufficient samples (≤10) were positive for VIM/IMP or NDM tests to calculate meaningful PPA values. The BD MAX Check-Points CPO assay represents an accurate tool for rapid recognition of patients with rectal colonization by the most commonly encountered CPOs.


Subject(s)
Bacterial Proteins/metabolism , Drug Resistance, Multiple, Bacterial/genetics , Gram-Negative Bacteria/enzymology , Gram-Negative Bacteria/genetics , beta-Lactamases/metabolism , Anti-Bacterial Agents/pharmacology , Bacterial Proteins/genetics , Bacteriological Techniques/methods , Carbapenems/pharmacology , Gene Expression Regulation, Bacterial , Gene Expression Regulation, Enzymologic , Humans , Multiplex Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/methods , Rectum/microbiology , Sensitivity and Specificity , beta-Lactamases/genetics
9.
Am J Clin Pathol ; 157(5): 781-788, 2022 05 04.
Article in English | MEDLINE | ID: mdl-34893797

ABSTRACT

OBJECTIVES: Aerococcus spp are Gram-positive cocci increasingly recognized as uropathogens. The Clinical and Laboratory Standards Institute recently published specific breakpoints for Aerococcus spp (M45, third edition); however, the standardized method used for antimicrobial susceptibility testing (AST) requires media not often maintained in clinical laboratories. The purpose of this study was to evaluate and compare alternative methods of AST for Aerococcus isolates. METHODS: AST was performed on 134 clinical isolates using the Etest on three different types of agar, Vitek 2, and BD Phoenix. These results were compared with broth microdilution using the Sensititre STP6F. RESULTS: Aerococcus exhibited low minimum inhibitory concentrations to benzylpenicillin, meropenem, linezolid, and vancomycin. Variable resistance was seen to levofloxacin, ceftriaxone, and tetracycline. Meropenem and vancomycin met all acceptance criteria with every alternative method tested. Benzylpenicillin and linezolid did not meet essential agreement on any AST method. Tetracycline met the majority of acceptance criteria with the exception of more than 3% very major error when using the Etest on chocolate agar, the Vitek 2, and BD Phoenix. CONCLUSIONS: Overall, the alternate AST method with the highest agreement with broth microdilution was the Etest on Mueller-Hinton agar with 5% sheep blood and may be an optimal alternative to broth microdilution.


Subject(s)
Aerococcus , Agar , Animals , Anti-Bacterial Agents/pharmacology , Humans , Linezolid/pharmacology , Meropenem , Microbial Sensitivity Tests , Sheep , Tetracyclines , Vancomycin
10.
Microbiol Spectr ; 9(2): e0084621, 2021 10 31.
Article in English | MEDLINE | ID: mdl-34668736

ABSTRACT

Isothermal amplification-based tests have been introduced as rapid, low-cost, and simple alternatives to real-time reverse transcriptase PCR (RT-PCR) tests for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection. The clinical performance of two isothermal amplification-based tests (Atila Biosystems iAMP coronavirus disease of 2019 [COVID-19] detection test and OptiGene COVID-19 direct plus RT-loop-mediated isothermal amplification [LAMP] test) was compared with that of clinical RT-PCR assays using different sampling strategies. A total of 1,378 participants were tested across 4 study sites. Compared with standard of care RT-PCR testing, the overall sensitivity and specificity of the Atila iAMP test for detection of SARS-CoV-2 were 76.2% and 94.9%, respectively, and increased to 88.8% and 89.5%, respectively, after exclusion of an outlier study site. Sensitivity varied based on the anatomic site from which the sample was collected. Sensitivity for nasopharyngeal sampling was 65.4% (range across study sites, 52.8% to 79.8%), for midturbinate was 88.2%, for saliva was 55.1% (range across study sites, 42.9% to 77.8%), and for anterior nares was 66.7% (range across study sites, 63.6% to 76.5%). The specificity for these anatomic collection sites ranged from 96.7% to 100%. Sensitivity improved in symptomatic patients (overall, 82.7%) and those with a higher viral load (overall, 92.4% for cycle threshold [CT] of ≤25). Sensitivity and specificity of the OptiGene direct plus RT-LAMP test, which was conducted at a single study site, were 25.5% and 100%, respectively. The Atila iAMP COVID test with midturbinate sampling is a rapid, low-cost assay for detecting SARS-CoV-2, especially in symptomatic patients and those with a high viral load, and could be used to reduce the risk of SARS-CoV-2 transmission in clinical settings. Variation of performance between study sites highlights the need for site-specific clinical validation of these assays before clinical adoption. IMPORTANCE Numerous SARS-CoV-2 detection assays have been developed and introduced into the market under emergency use authorizations (EUAs). EUAs are granted primarily based on small studies of analytic sensitivity and specificity with limited clinical validations. A thorough clinical performance evaluation of SARS-CoV-2 assays is important to understand the strengths, limitations, and specific applications of these assays. In this first large-scale multicentric study, we evaluated the clinical performance and operational characteristics of two isothermal amplification-based SARS-CoV-2 tests, namely, (i) iAMP COVID-19 detection test (Atila BioSystems, USA) and (ii) COVID-19 direct plus RT-LAMP test (OptiGene Ltd., UK), compared with those of clinical RT-PCR tests using different sampling strategies (i.e., nasopharyngeal, self-sampled anterior nares, self-sampled midturbinate, and saliva). An important specific use for these isothermal amplification-based, rapid, low-cost, and easy-to-perform SARS-CoV-2 assays is to allow for a safer return to preventive clinical encounters, such as cancer screening, particularly in low- and middle-income countries that have low SARS-CoV-2 vaccination rates.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , Molecular Diagnostic Techniques/methods , Nucleic Acid Amplification Techniques/methods , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Humans , Limit of Detection , Mass Screening , Nasopharynx/virology , Point-of-Care Systems , RNA, Viral/analysis , Reverse Transcriptase Polymerase Chain Reaction/methods , Specimen Handling , Viral Load
11.
medRxiv ; 2021 Jul 06.
Article in English | MEDLINE | ID: mdl-34268516

ABSTRACT

BACKGROUND: Isothermal amplification-based tests were developed as rapid, low-cost, and simple alternatives to real-time reverse transcriptase-polymerase chain reaction (RT-PCR) tests for SARS-COV-2 detection. METHODS: Clinical performance of two isothermal amplification-based tests (Atila Biosystems iAMP COVID-19 detection test and OptiGene COVID-19 Direct Plus RT-LAMP test) was compared to clinical RT-PCR assays using different sampling strategies. A total of 1378 participants were tested across four study sites. RESULTS: Compared to standard of care RT-PCR testing, the overall sensitivity and specificity of the Atila iAMP test for detection of SARS-CoV-2 were 76.2% and 94.9%, respectively, and increased to 88.8% and 89.5%, respectively, after exclusion of an outlier study site. Sensitivity varied based on the anatomic collected site. Sensitivity for nasopharyngeal was 65.4% (range across study sites:52.8%-79.8%), mid-turbinate 88.2%, saliva 55.1% (range across study sites:42.9%-77.8%) and anterior nares 66.7% (range across study sites:63.6%-76.5%). The specificity for these anatomic collection sites ranged from 96.7% to 100%. Sensitivity improved in symptomatic patients (overall 82.7%) and those with a higher viral load (overall 92.4% for ct≤25). Sensitivity and specificity of the OptiGene Direct Plus RT-LAMP test, conducted at a single study-site, were 25.5% and 100%, respectively. CONCLUSIONS: The Atila iAMP COVID test with mid-turbinate sampling is a rapid, low-cost assay for detecting SARS-COV-2, especially in symptomatic patients and those with a high viral load, and could be used to reduce the risk of SARS-COV-2 transmission in clinical settings. Variation of performance between study sites highlights the need for site-specific clinical validation of these assays before clinical adoption.

12.
Am J Clin Pathol ; 156(1): 24-33, 2021 06 17.
Article in English | MEDLINE | ID: mdl-33940605

ABSTRACT

OBJECTIVES: We conducted an analytic and clinical comparison of a novel high-definition polymerase chain reaction PCR (HDPCR) assay to traditional real-time PCR (RT-PCR) for the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in upper respiratory specimens. METHODS: Analytic performance of RT-PCR, HDPCR, and extraction-free HDPCR was established through replicate testing of a serially diluted clinical specimen containing SARS-CoV-2. A clinical comparison of all 3 assays was conducted using 351 prospectively collected upper respiratory swab specimens obtained from symptomatic and asymptomatic individuals collected in various transport media. RESULTS: RT-PCR and HDPCR assays using extracted nucleic acid demonstrated similar analytic limits of detection (LoD) and clinical performance, with 100% positive and negative agreement. Extraction-free HDPCR demonstrated a 1.5 to 2.0 log10 increase in LoD based on cycle threshold values. However, clinical performance of extraction-free HDPCR remained high, demonstrating 97.8% positive and 99.6% negative agreement with RT-PCR. An overall increase in "invalid" and "presumptive" results was observed when using the extraction-free method, but this was highly variable based on transport medium used. CONCLUSIONS: HDPCR performs similar to RT-PCR for the detection of SARS-CoV-2. The use of an extraction-free HDPCR protocol maintained high clinical performance despite reduced analytic LoD, with the benefit of reduced hands-on time and cost of reagents associated with nucleic acid extraction.


Subject(s)
COVID-19/genetics , RNA, Viral/analysis , Real-Time Polymerase Chain Reaction , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19 Testing/methods , Humans , Limit of Detection , Real-Time Polymerase Chain Reaction/methods , SARS-CoV-2/pathogenicity , Sensitivity and Specificity , Specimen Handling/methods
13.
PLoS One ; 16(3): e0249203, 2021.
Article in English | MEDLINE | ID: mdl-33770124

ABSTRACT

The emergence and evolution of antibiotic resistance has been accelerated due to the widespread use of antibiotics and a lack of timely diagnostic tests that guide therapeutic treatment with adequate sensitivity, specificity, and antimicrobial susceptibility testing (AST) accuracy. Automated AST instruments are extensively used in clinical microbiology labs and provide a streamlined workflow, simplifying susceptibility testing for pathogenic bacteria isolated from clinical samples. Although currently used commercial systems such as the Vitek2 and BD Phoenix can deliver results in substantially less time than conventional methods, their dependence on traditional AST inoculum concentrations and optical detection limit their speed somewhat. Herein, we describe the GeneFluidics ProMax lab automation system intended for a rapid 3.5-hour molecular AST from clinical isolates. The detection method described utilizes a higher starting inoculum concentration and automated molecular quantification of species-specific 16S rRNA through the use of an electrochemical sensor to assess microbiological responses to antibiotic exposure. A panel of clinical isolates consisting of species of gram-negative rods from the CDC AR bank and two hospitals, New York-Presbyterian Queens and Medical College of Wisconsin, were evaluated against ciprofloxacin, gentamicin, and meropenem in a series of reproducibility and clinical studies. The categorical agreement and reproducibility for Citrobacter freundii, Enterobacter cloacae, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, and Pseudomonas aeruginosa were 100% and 100% for ciprofloxacin, 98.7% and 100% for gentamicin and 98.5% and 98.5% for meropenem, respectively.


Subject(s)
Anti-Bacterial Agents/pharmacology , Gram-Negative Bacteria/drug effects , Microbial Sensitivity Tests , Phenotype , Feasibility Studies , Species Specificity
14.
J Clin Microbiol ; 59(1)2020 12 17.
Article in English | MEDLINE | ID: mdl-33087433

ABSTRACT

Group B Streptococcus (GBS) can be found to colonize about 25% of all healthy, adult women and is the leading infectious cause of early neonatal morbidity and mortality in the United States. This study evaluated the clinical performance of PhenoMatrix (PM) chromogenic detection module (CDM) digital imaging software in detection of GBS from LIM broth plated on ChromID Strepto B chromogenic medium (ChromID) using the WASP automated processor. The performance of the PM CDM was compared to manual culture review of the digital images and molecular detection of GBS. ChromID alone had a sensitivity and specificity of 84.5% and 94.7%, respectively, after 48 h compared to nucleic acid amplification testing (NAAT). Compared to the composite reference for positivity, when PM CDM was used to detect GBS from ChromID, the sensitivity was 100%, with no true-positive GBS isolates missed by 48 h of incubation. Overall, evaluating all three methods for the detection of GBS, the sensitivities of NAAT, ChromID plus PM CDM at 48 h, and ChromID alone at 48 h were 96.8%, 95.5%, and 90.3%, respectively. The specificities of NAAT, ChromID plus PM CDM, and ChromID alone were 97.7%, 63.0%, and 95.4%, respectively. The sensitivity of ChromID in combination with the PM CDM was similar to the sensitivity of molecular detection. Further, the algorithm never called a culture negative that was determined to be positive by manual reading, and it identified an additional eight true positive specimens that were missed by manual digital image culture reading.


Subject(s)
Pregnancy Complications, Infectious , Streptococcal Infections , Adult , Algorithms , Bacteriological Techniques , Culture Media , Female , Humans , Infant, Newborn , Pregnancy , Sensitivity and Specificity , Streptococcal Infections/diagnosis , Streptococcus agalactiae , Vagina
15.
Diagnostics (Basel) ; 10(10)2020 Sep 24.
Article in English | MEDLINE | ID: mdl-32987722

ABSTRACT

Quantitative reverse transcription polymerase chain reaction (RT-qPCR) assay is the gold standard recommended to test for acute SARS-CoV-2 infection. However, it generally requires expensive equipment such as RNA isolation instruments and real-time PCR thermal cyclers. As a pandemic, COVID-19 has spread indiscriminately, and many low resource settings and developing countries do not have the means for fast and accurate COVID-19 detection to control the outbreak. Additionally, long assay times, in part caused by slow sample preparation steps, have created a large backlog when testing patient samples suspected of COVID-19. With many PCR-based molecular assays including an extraction step, this can take a significant amount of time and labor, especially if the extraction is performed manually. Using COVID-19 clinical specimens, we have collected evidence that the RT-qPCR assay can feasibly be performed directly on patient sample material in virus transport medium (VTM) without an RNA extraction step, while still producing sensitive test results. If RNA extraction steps can be omitted without significantly affecting clinical sensitivity, the turn-around time of COVID-19 tests, and the backlog we currently experience can be reduced drastically. Furthermore, our data suggest that rapid RT-PCR can be implemented for sensitive and specific molecular diagnosis of COVID-19 in locations where sophisticated laboratory instruments are not available. Our USD 300 set up achieved rapid RT-PCR using thin-walled PCR tubes and a water bath setup using sous vide immersion heaters, a Raspberry Pi computer, and a single servo motor that can process up to 96 samples at a time. Using COVID-19 positive clinical specimens, we demonstrated that RT-PCR assays can be performed in as little as 12 min using untreated samples, heat-inactivated samples, or extracted RNA templates with our low-cost water bath setup. These findings can help rapid COVID-19 testing to become more accessible and attainable across the globe.

16.
Am J Clin Pathol ; 154(4): 479-485, 2020 09 08.
Article in English | MEDLINE | ID: mdl-32687186

ABSTRACT

OBJECTIVES: We examined the distribution of reverse transcription polymerase chain reaction (RT-PCR) cycle threshold (CT) values obtained from symptomatic patients being evaluated for coronavirus disease 2019 (COVID-19) to determine the proportion of specimens containing a viral load near the assay limit of detection (LoD) to gain practical insight to the risk of false-negative results. We also examined the relationship between CT value and patient age to determine any age-dependent difference in viral load or test sensitivity. METHODS: We collected CT values obtained from the cobas severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) assay corresponding to 1,213 combined nasopharyngeal-oropharyngeal specimens obtained from symptomatic individuals that were reported as positive or presumptive positive for SARS-CoV-2. CT values were stratified by SARS-CoV target and patient age group. RESULTS: In total, 93.3% to 98.4% of specimens demonstrated CT values greater than 3× the assay LoD, at which point false-negative results would not be expected. The mean of CT values between age groups was statistically equivalent with the exception of patients in age group 80 to 89 years, which demonstrated slightly lower CTs. CONCLUSIONS: Based on the distribution of observed CT values, including the small proportion of specimens with values near the assay LoD, there is a low risk of false-negative RT-PCR results in combined nasopharyngeal-oropharyngeal specimens obtained from symptomatic individuals.


Subject(s)
Betacoronavirus/isolation & purification , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Limit of Detection , Pneumonia, Viral/diagnosis , RNA, Viral/isolation & purification , Reverse Transcriptase Polymerase Chain Reaction , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Betacoronavirus/genetics , COVID-19 , COVID-19 Testing , Child , Child, Preschool , Coronavirus Infections/virology , False Negative Reactions , Female , Humans , Infant , Infant, Newborn , Male , Middle Aged , Pandemics , Pneumonia, Viral/virology , RNA, Viral/analysis , SARS-CoV-2 , Sensitivity and Specificity , Viral Load , Wisconsin , Young Adult
17.
J Clin Microbiol ; 58(7)2020 06 24.
Article in English | MEDLINE | ID: mdl-32350045

ABSTRACT

Lower respiratory tract infections, including hospital-acquired and ventilator-associated pneumonia, are common in hospitalized patient populations. Standard methods frequently fail to identify the infectious etiology due to the polymicrobial nature of respiratory specimens and the necessity of ordering specific tests to identify viral agents. The potential severity of these infections combined with a failure to clearly identify the causative pathogen results in administration of empirical antibiotic agents based on clinical presentation and other risk factors. We examined the impact of the multiplexed, semiquantitative BioFire FilmArray Pneumonia panel (PN panel) test on laboratory reporting for 259 adult inpatients submitting bronchoalveolar lavage (BAL) specimens for laboratory analysis. The PN panel demonstrated a combined 96.2% positive percent agreement (PPA) and 98.1% negative percent agreement (NPA) for the qualitative identification of 15 bacterial targets compared to routine bacterial culture. Semiquantitative values reported by the PN panel were frequently higher than values reported by culture, resulting in semiquantitative agreement (within the same log10 value) of 43.6% between the PN panel and culture; however, all bacterial targets reported as >105 CFU/ml in culture were reported as ≥105 genomic copies/ml by the PN panel. Viral targets were identified by the PN panel in 17.7% of specimens tested, of which 39.1% were detected in conjunction with a bacterial target. A review of patient medical records, including clinically prescribed antibiotics, revealed the potential for antibiotic adjustment in 70.7% of patients based on the PN panel result, including discontinuation or de-escalation in 48.2% of patients, resulting in an average savings of 6.2 antibiotic days/patient.


Subject(s)
Antimicrobial Stewardship , Pneumonia , Respiratory Tract Infections , Adult , Humans , Molecular Diagnostic Techniques , Multiplex Polymerase Chain Reaction , Respiratory Tract Infections/diagnosis , Respiratory Tract Infections/drug therapy
18.
J Clin Microbiol ; 58(7)2020 06 24.
Article in English | MEDLINE | ID: mdl-32376668

ABSTRACT

NG-Test Carba 5 is a rapid in vitro multiplex immunoassay for the phenotypic detection and differentiation of five common carbapenemase families (KPC, OXA-48-like, VIM, IMP, and NDM) directly from bacterial colonies. The assay is simple to perform and has recently received U.S. Food and Drug Administration clearance. A method comparison study was performed at geographically diverse medical centers (n = 3) in the United States, where 309 Enterobacterales and Pseudomonas aeruginosa isolates were evaluated by NG-Test Carba 5 (NG Biotech, Guipry, France), the Xpert Carba-R assay (Cepheid, Inc., Sunnyvale, CA), the modified carbapenem inactivation method (mCIM), the EDTA-modified carbapenem inactivation method, and disk diffusion with carbapenems. Colonies from tryptic soy agar with 5% sheep blood (blood agar) and MacConkey agar were tested, and the results were compared to those obtained by a composite reference method. Additionally, a fourth medical center performed a medium comparison study by evaluating the performance characteristics of NG-Test Carba 5 from blood, MacConkey, and Mueller-Hinton agars with 110 isolates of Enterobacterales and P. aeruginosa These results were compared to the expected genotypic and mCIM results. For the multicenter method comparison study, the overall positive percent agreement (PPA) and the overall negative percent agreement (NPA) of NG-Test Carba 5 with the composite reference method were 100% for both blood and MacConkey agars. The medium comparison study at the fourth site showed that the PPA ranged from 98.9% to 100% and that the NPA ranged from 95.2% to 100% for blood, MacConkey, and Mueller-Hinton agars. NG-Test Carba 5 accurately detected and differentiated five common carbapenemase families from Enterobacterales and P. aeruginosa colonies on commonly used agar media. The results of this test will support a streamlined laboratory work flow and will expedite therapeutic and infection control decisions.


Subject(s)
Bacterial Proteins , beta-Lactamases , Animals , Bacterial Proteins/genetics , France , Sensitivity and Specificity , Sheep , beta-Lactamases/genetics
19.
J Clin Microbiol ; 58(4)2020 03 25.
Article in English | MEDLINE | ID: mdl-31941690

ABSTRACT

Automation of the clinical microbiology laboratory has become more prominent as laboratories face higher specimen volumes and understaffing and are becoming more consolidated. One recent advancement is the use of digital image analysis to rapidly distinguish between chromogenic growth for screening bacterial cultures. In this study, colony segregation software developed by Copan (Brescia, Italy) was evaluated to distinguish between significant growth and no growth of urine cultures plated onto standard blood and MacConkey agars. Specimens from 3 sites were processed on a WASP instrument (Copan) and incubated on the WASPLab platform (Copan), and plates were imaged at 0 and 24 hours postinoculation. Images were read by technologists following validated laboratory protocols (VLPs), and results were recorded in the laboratory information systems (LIS). Image analysis performed colony counts on the 24-hour images, and results were compared with the VLP. A total of 12,931 urine cultures were tested and analyzed with an overall sensitivity and specificity of 99.8% and 72.0%, respectively. After secondary review, 91.1% of manual-positive/automation-negative specimens were due to expert rules that reported the plate as contaminated or growing only normal flora and not due to threshold counts. Nine specimens were found to be manual-positive/automation-negative; a secondary review demonstrated that the results of 8 of these specimens were due to growth of microcolonies that were programmed to be ignored by the software and 1 were due to a colony count near the limit of significance. Overall, the image analysis software proved to be highly sensitive and can be utilized by laboratories to batch-review negative cultures to improve laboratory workflow.


Subject(s)
Automation, Laboratory , Bacteriological Techniques , Culture Media , Humans , Italy , Software , Urine
20.
Infect Control Hosp Epidemiol ; 41(3): 358-360, 2020 03.
Article in English | MEDLINE | ID: mdl-31918767

ABSTRACT

Previously, we showed that disinfection of sink drains is effective at decreasing bacterial loads. Here, we report our evaluation of the ideal frequency of sink-drain disinfection and our comparison of 2 different hydrogen peroxide disinfectants.


Subject(s)
Disinfectants/pharmacology , Disinfection/methods , Equipment Contamination/prevention & control , Cross Infection/prevention & control , Humans , Water Microbiology , Wisconsin
SELECTION OF CITATIONS